uPVC Column Pipes   uPVC Pressure Pipes   uPVC Plumbing Pipes
Quality with Experience & Technology
Column Pipes, uPVC Column Pipes, Column Pipes Manufacturer, uPVC Column Pipes Manufacturer, Column Pipes Exporter, uPVC Column Pipes Exporter, Column Pipes Supplier, uPVC Column Pipes Supplier, Column Pipes Manufacturer & Exporter in India, Gujarat, Rajkot

uPVC Column Pipes

Manufacturer, Exporter & Supplier of Column Pipes, uPVC Column Pipes in India, Gujarat, Rajkot…

 

Captain Pipes › uPVC Column Pipes

 
Range

1” to 5” outer diameter (25 mm to 125 mm Nominal Diameter).

Color

White

Length

Available in 3 meters    (Also available in 2.8 meters for exports)

Available in multi grades

Tiny, Medium Deluxe, Medium Deluxe Plus, Medium,
Standard Deluxe, Standard Deluxe Plus, Standard,
Heavy, Super Heavy

 
 

Some special properties of uPVC Column pipes are as follows-

  • Suitable for potable water supplies
  • High Izod impact strength
  • High tensile strength
  • High torque resistant
  • 100% leak proof
  • Economically satisfied
  • Minimum frictional losses thus saving power
  • High flow characteristics
  • 25% higher discharge than G.I pipes
  • Cost effective
  • Light weight offers total economy in handling, transportation & installation
  • Seamless, strong & resilient
  • Odorless and hygienic for potable water
  • Longer lasting PVC is free from weakness caused by formation, rusting and weathering.

Silent features of our Column Pipes, Couplers and its accessories :-

  • Square Threads of pipes as well as coupler gives a very high tensile load capacity, high Izod impact and easy fitment, re-fitment and longer life.
  • The rubber dampeners, sealent system provides leak proof fittings and also absorbs the vibration of the pump which results in longer life of motor and pump bearing.
  • Our square threads of pipes as well as coupler are of best designed and manufactured in CNC machines in order to provide best accuracy and quality.
  • The rubber ring like Step ring, L-ring, O-ring & Seal ring are of natural rubber and best to absorb the shock of motor.
  • Our thick and thin portion of the pipes has been so developed to absorb the full torque produced due to motor thus resulting long life.
  • The technically developed adapters have 11 TPI metric threads at one end which fits into motor and square threads at one end which fits into column pipes.
 

Applications

  • Water rising for submersible pump set.
  • It is commonly used as replacement on the place for MS, ERW, GI, HDPE and stainless steel.
 

Technical Parameters of uPVC Column Pipes

Product Range

 
Nominal DiameterOuter
Diameter
(Avg.)
mm
Technical ParametersGrade
inchmmTinyMedium
Deluxe
Medium
Deluxe
Plus
MediumStandard DeluxeStandard Deluxe
Plus
StandardHeavySuper
Heavy
1.00" 25 33.35 End Wall Thickness Avg. (mm) 2.90     3.80     5.00 5.35 5.90
Allowable Hydrostatics Pressure (kgf/cm2) 12.00     18.00     20.00 22.00 25.00
Ultimate Breaking Load (Kgs.) 1200     1900     2000 2200 2500
Recommedable Depth (Feet) 120     350     500 700 800
1.25" 32 42.15 End Wall Thickness Avg. (mm) 3.65   3.90 4.40     5.10 5.60 6.10
Allowable Hydrostatics Pressure (kgf/cm2) 15.00   20.00 20.00     22.00 25.00 30.00
Ultimate Breaking Load (Kgs.) 1700   1900 2000     2800 3300 3500
Recommedable Depth (Feet) 120   300 350     500 700 800
1.50" 40 48.15 End Wall Thickness Avg. (mm) 4.13     4.40     5.35 6.15 8.50
Allowable Hydrostatics Pressure (kgf/cm2) 15.00     20     30.00 35.00 40.00
Ultimate Breaking Load (Kgs.) 2200     2700     3200 4400 4500
Recommedable Depth (Feet) 150     350     500 700 800
2.00" 50 60.10 End Wall Thickness Avg. (mm) 4.20     4.95 5.30 6.00 6.55 7.65 9.20
Allowable Hydrostatics Pressure (kgf/cm2) 15.00     20.00 25.00 28.00 30.00 35.00 45.00
Ultimate Breaking Load (Kgs.) 2800     3100 3400 3700 4000 4800 6000
Recommedable Depth (Feet) 150     350 400 450 550 1100 1500
2.25" 60 65.45 End Wall Thickness Avg. (mm) -         8.10 9.10
Allowable Hydrostatics Pressure (kgf/cm2) -     -       40.00 45.00
Ultimate Breaking Load (Kgs.) -     -       5000 6500
Recommedable Depth (Feet) -     -       1200 1500
2.50" 65 75.30 End Wall Thickness Avg. (mm) 4.70     6.00 6.65 6.85 7.45 8.70 10.40
Allowable Hydrostatics Pressure (kgf/cm2) 25.00     30.00 32.00 33.00 35.00 40.00 45.00
Ultimate Breaking Load (Kgs.) 3500     5000 5800 6500 7000 9000 12000
Recommedable Depth (Feet) 150     350 400 450 550 1200 1500
3.00" 80 88.80 End Wall Thickness Avg. (mm) 6.05     6.35 6.60 6.70 7.80 10.15 12.00
Allowable Hydrostatics Pressure (kgf/cm2) 25.00     30.00 32.00 33.00 35.00 40.00 45.00
Ultimate Breaking Load (Kgs.) 5000     5500 6800 7000 7200 10000 15000
Recommedable Depth (Feet) 150     350 400 450 550 1200 1500
4.00" 100 114.25 End Wall Thickness Avg. (mm) 5.75     6.68   7.70 8.40 12.15 15.00
Allowable Hydrostatics Pressure (kgf/cm2) 25.00     30.00   33.00 35.00 40.00 45.00
Ultimate Breaking Load (Kgs.) 7400     7800     12000 18000 22000
Recommedable Depth (Feet) 150     350     550 1200 1500
5.00" 125 140.05 End Wall Thickness Avg. (mm)         10.90 15.25 18.50
Allowable Hydrostatics Pressure (kgf/cm2) -     -     45.00 50.00 50.00
Ultimate Breaking Load (Kgs.) -     -     18000 25000 33000
Recommedable Depth (Feet) -     -     600 1200 1500